Water Storage Tank Installation


Back to Index

Excavation
Maximum back fill cover (A) 30"
Minimum backfill cover (A) 6"
Bedding (C)
Bedding should be a well compacted sand/gravel mixture: 6" minimum in soil terrain, 12" minimum in rock terrain.
Tee & Gasket Installation
A.  Install neoprene gasket into pre-formed hub area.
B.  Install pipe through gasket and make connection to 4" sanitary tee. Solvent weld cement is recommended for making connections.
C.  Tees should be located directly under inspection ports/manhole opening.
NOTE: It is recommended that you check with your local sanitarian for information regarding tee extensions, etc.
Backfilling Exterior
A.  Pre-Install cover and/or manhole extension and cover before backfilling
B.  Backfill with 12" maximum layers of sand/gravel mixture. It is important that layers be well compacted. Always compact ends first.
C.  Fill tank with water in equal proportion to backfill.
D.  Be certain to compact backfill under inlet and outlet pipe.
Backfilling the Top
A.  When the tank is filled with water, backfill to the surrounding level.
General Notes:
1.  Do not use these tanks for drinking water.
2.  Always refill the tank with water following periodic pumping.
3.  Do not install across path of vehicles or heavy equipment.
4.  Do not install these tanks in excessive high water table areas.
5.  These tanks are designed for use as an underground tank only. These tanks (with the exception of the 300 gal.model) cannot be used as a holding tank or pump chamber.
Failure to comply with these procedures and general notes will void warranty.


Install 1








Install 2








Install 3







Back to Index
Site Map

American Containers, Inc.
10471 Mammoth Ave.
Baton Rouge, LA 70814
Phone: 225-927-1670
Toll Free: 800-979-3536
Fax: 225-927-6160

jerry@americancontainersinc.com